mirror of https://github.com/xzeldon/htop.git
238 lines
6.5 KiB
Groff
238 lines
6.5 KiB
Groff
|
.TH "PCP-HTOP" "5" "2021" "@PACKAGE_STRING@" "File Formats"
|
||
|
.SH "NAME"
|
||
|
\f3pcp-htop\f1 \- pcp-htop configuration file
|
||
|
.SH "DESCRIPTION"
|
||
|
.B pcp-htop
|
||
|
is a customizable performance metrics reporting tool.
|
||
|
It has a dynamic architecture, where a set of configuration files
|
||
|
provide additional, optional meters and columns to extend the fixed
|
||
|
set of display options provided by regular
|
||
|
.BR htop .
|
||
|
.LP
|
||
|
These configuration files can be provided from both system-wide
|
||
|
locations (first
|
||
|
.I @sysconfdir@/pcp/htop
|
||
|
then
|
||
|
.IR @datarootdir@/pcp/htop )
|
||
|
and below the users home directory (usually
|
||
|
.IR ~/.config/htop ).
|
||
|
Within these locations the
|
||
|
.I meters
|
||
|
and
|
||
|
.I columns
|
||
|
are scanned for dynamic Meter and Column specifications.
|
||
|
.LP
|
||
|
Meters are displayed in the top part of the
|
||
|
.B pcp-htop
|
||
|
window, and columns are display in the lower part.
|
||
|
Meters tend to display system-wide metrics, and Columns
|
||
|
display metrics about individual processes.
|
||
|
.LP
|
||
|
The formats are similar but have slightly different requirements.
|
||
|
Both formats follow the common ini-style, also allowing both empty
|
||
|
lines and comment lines starting with the "#" character.
|
||
|
.SH "METERS"
|
||
|
The following is an example configuration for a new Redis meter:
|
||
|
.LP
|
||
|
.ft CW
|
||
|
.nf
|
||
|
.in +0.5i
|
||
|
[redisclient]
|
||
|
caption = Redis clients
|
||
|
type = bar
|
||
|
blocked.metric = redis.blocked_clients
|
||
|
blocked.color = blue
|
||
|
blocked.label = blk
|
||
|
clients.metric = redis.connected_clients
|
||
|
clients.color = green
|
||
|
clients.label = conn
|
||
|
.in
|
||
|
.fi
|
||
|
.ft 1
|
||
|
.LP
|
||
|
A configuration file can contain multiple meter definitions.
|
||
|
Each definition begins with a identifying name enclosed by
|
||
|
square brackets \-
|
||
|
.I redisclient
|
||
|
in this example.
|
||
|
The name is used internally within
|
||
|
.B pcp-htop
|
||
|
and must be unique, must begin with an alphabetic character,
|
||
|
and may subsequently only contain alphanumeric characters or
|
||
|
the underscore character.
|
||
|
No whitespace or other characters are allowed.
|
||
|
.LP
|
||
|
There are several parameters that define the way the meter
|
||
|
will be displayed to the user.
|
||
|
.TP 5
|
||
|
.B caption
|
||
|
This value is displayed on the Setup screen once the meter
|
||
|
has been selected.
|
||
|
A truncated version of the
|
||
|
.I caption
|
||
|
will also be displayed (followed by a colon) on the primary
|
||
|
display while the meter is updating.
|
||
|
.TP
|
||
|
.B description
|
||
|
This can be used to provide more detail during the meter
|
||
|
selection process on the Setup screen, and if present it is
|
||
|
displayed in the "Available Meters" column.
|
||
|
If not present, the
|
||
|
.B caption
|
||
|
will be used for this.
|
||
|
If neither is present, the internal (mandatory)
|
||
|
.B name
|
||
|
will be used.
|
||
|
.TP
|
||
|
.B type
|
||
|
This setting allows a preferred default meter type to be specified.
|
||
|
The associated value must be one of
|
||
|
.IR bar ,
|
||
|
.IR text ,
|
||
|
.IR graph ,
|
||
|
or
|
||
|
.IR led .
|
||
|
If no value is provided for a dynamic meter, the default value of
|
||
|
.IR text
|
||
|
will be used.
|
||
|
.TP
|
||
|
.B maximum
|
||
|
A numeric value can also be set to size the meter, such that
|
||
|
values (e.g. for a
|
||
|
.I bar
|
||
|
type meter display) will be scaled within range zero to
|
||
|
.IR maximum .
|
||
|
.LP
|
||
|
The remaining definition syntax describes the individual
|
||
|
metric(s) which will be used to animate the meter.
|
||
|
One or more metrics must be specified for each meter and
|
||
|
there are several properties associated with each.
|
||
|
Once again, these metrics must be named (the same rules
|
||
|
described above for meters apply here) and the following
|
||
|
properties can be configured:
|
||
|
.TP 5
|
||
|
.B name.metric
|
||
|
This is the only mandatory field and associates a PCP metric
|
||
|
with the meter.
|
||
|
Values sampled for each metric at runtime provide the
|
||
|
animation visible in the
|
||
|
.B pcp-htop
|
||
|
display.
|
||
|
The metric specification can be either a PCP metric name as
|
||
|
listed by
|
||
|
.BR pminfo (1)
|
||
|
or a "derived" metric expression.
|
||
|
The format for derived metric expressions is described on the
|
||
|
.BR pmRegisterDerived (3)
|
||
|
manual page.
|
||
|
.TP
|
||
|
.B name.color
|
||
|
Setting color to be used when rendering metric values.
|
||
|
Possible values are
|
||
|
.IR red ,
|
||
|
.IR green ,
|
||
|
.IR blue ,
|
||
|
.IR cyan ,
|
||
|
.IR magenta ,
|
||
|
.IR yellow ,
|
||
|
.IR gray ,
|
||
|
.I darkgray
|
||
|
or
|
||
|
.IR white .
|
||
|
.TP
|
||
|
.B name.label
|
||
|
An optional, short label to display before the metric value.
|
||
|
The ":" character will be appended to the
|
||
|
.I label
|
||
|
before the metric value part of the display.
|
||
|
.TP
|
||
|
.B name.suffix
|
||
|
An optional, short suffix to display after the metric value.
|
||
|
Commonly used to indicate values as a percentage using a "%"
|
||
|
.I suffix
|
||
|
value and to provide the base unit of measurement.
|
||
|
Note that since PCP maintains units for metrics, for those
|
||
|
metrics that have dimension in "space" (bytes, kilobytes,
|
||
|
megabytes, etc), a suffix will be automatically appended.
|
||
|
.SH "COLUMNS"
|
||
|
The following is an example configuration for a new column
|
||
|
showing open file descriptors for each process:
|
||
|
.LP
|
||
|
.ft CW
|
||
|
.nf
|
||
|
.in +0.5i
|
||
|
[openfds]
|
||
|
heading = FDS
|
||
|
caption = FDCOUNT
|
||
|
description = Open file descriptors
|
||
|
metric = proc.fd.count
|
||
|
width = 3
|
||
|
.in
|
||
|
.fi
|
||
|
.ft 1
|
||
|
.LP
|
||
|
A configuration file can contain multiple column definitions.
|
||
|
Each definition begins with a identifying name enclosed
|
||
|
by square brackets \-
|
||
|
.I openfds
|
||
|
in this example, and the same rules apply as described above
|
||
|
for meter names.
|
||
|
.LP
|
||
|
Each column must specify a metric.
|
||
|
Optional parameters can also be set.
|
||
|
.TP 5
|
||
|
.B metric
|
||
|
As with meters, the metric value must be either a PCP metric
|
||
|
name as listed by
|
||
|
.BR pminfo (1)
|
||
|
or a derived metric.
|
||
|
The metric must have an instance domain (set of values) and
|
||
|
that instance domain must map to the set of processes with
|
||
|
the instance identifier being PIDs (process identifiers).
|
||
|
Typically this will be metrics from the
|
||
|
.I proc
|
||
|
or
|
||
|
.I hotproc
|
||
|
namespace (\c
|
||
|
.BR pmdaproc (1)),
|
||
|
but metrics from other domains (\c
|
||
|
.BR pmdabcc (1),
|
||
|
.BR pmdabpf (1),
|
||
|
etc) that have per-process values are equally applicable.
|
||
|
.TP
|
||
|
.B width
|
||
|
Column width to use when displaying values for the metric.
|
||
|
A negative value can be used to specify left alignment.
|
||
|
An upper column limit of 28 characters is enforced.
|
||
|
The default column width is 5 characters.
|
||
|
.TP
|
||
|
.B heading
|
||
|
The short title that will be displayed at the head of the
|
||
|
column \- usually a short, cryptic, all uppercase string.
|
||
|
.TP
|
||
|
.B caption
|
||
|
A short identifying word presented to users on the Setup
|
||
|
screen under both the Available and Active Columns lists.
|
||
|
.TP
|
||
|
.B description
|
||
|
Text that assists users to understand the meaning of this
|
||
|
column when it is being presented via the Setup screen in
|
||
|
the Available Columns list.
|
||
|
.SH "SEE ALSO"
|
||
|
.BR pcp-htop (1),
|
||
|
.BR pminfo (1),
|
||
|
.BR pmcd (1),
|
||
|
.BR pmdaproc (1),
|
||
|
.BR pmdabcc (1),
|
||
|
.BR pmdabpf (1)
|
||
|
and
|
||
|
.BR pmRegisterDerived (3).
|
||
|
.SH "AUTHORS"
|
||
|
.B htop
|
||
|
was originally developed by Hisham Muhammad.
|
||
|
Nowadays it is maintained by the community at <htop@groups.io>.
|
||
|
.LP
|
||
|
.B pcp-htop
|
||
|
is maintained as a collaboration between the <htop@groups.io> and <pcp@groups.io>
|
||
|
communities, and forms part of the Performance Co-Pilot suite of tools.
|