htop/darwin/Platform.h

120 lines
3.5 KiB
C
Raw Normal View History

#ifndef HEADER_Platform
#define HEADER_Platform
/*
htop - darwin/Platform.h
(C) 2014 Hisham H. Muhammad
(C) 2015 David C. Hunt
Released under the GNU GPLv2+, see the COPYING file
in the source distribution for its full text.
*/
#include <stdbool.h>
#include <sys/types.h>
#include "Action.h"
#include "BatteryMeter.h"
#include "CPUMeter.h"
#include "DiskIOMeter.h"
#include "Hashtable.h"
#include "NetworkIOMeter.h"
#include "ProcessLocksScreen.h"
#include "SignalsPanel.h"
#include "CommandLine.h"
#include "darwin/DarwinProcess.h"
#include "generic/gettime.h"
#include "generic/hostname.h"
#include "generic/uname.h"
2020-12-19 17:10:03 +00:00
extern const ProcessField Platform_defaultFields[];
extern const SignalItem Platform_signals[];
extern const unsigned int Platform_numberOfSignals;
2020-10-05 11:19:50 +00:00
extern const MeterClass* const Platform_meterTypes[];
bool Platform_init(void);
// Converts ticks in the Mach "timebase" to nanoseconds.
// See `mach_timebase_info`, as used to define the `Platform_nanosecondsPerMachTick` constant.
uint64_t Platform_machTicksToNanoseconds(uint64_t mach_ticks);
// Converts "scheduler ticks" to nanoseconds.
// See `sysconf(_SC_CLK_TCK)`, as used to define the `Platform_nanosecondsPerSchedulerTick` constant.
double Platform_schedulerTicksToNanoseconds(const double scheduler_ticks);
void Platform_done(void);
void Platform_setBindings(Htop_Action* keys);
int Platform_getUptime(void);
void Platform_getLoadAverage(double* one, double* five, double* fifteen);
int Platform_getMaxPid(void);
double Platform_setCPUValues(Meter* mtr, unsigned int cpu);
2015-07-14 02:02:40 +00:00
void Platform_setMemoryValues(Meter* mtr);
2015-11-16 17:32:22 +00:00
void Platform_setSwapValues(Meter* mtr);
void Platform_setZfsArcValues(Meter* this);
2019-07-07 21:30:37 +00:00
void Platform_setZfsCompressedArcValues(Meter* this);
char* Platform_getProcessEnv(pid_t pid);
char* Platform_getInodeFilename(pid_t pid, ino_t inode);
FileLocks_ProcessData* Platform_getProcessLocks(pid_t pid);
bool Platform_getDiskIO(DiskIOData* data);
bool Platform_getNetworkIO(NetworkIOData* data);
2020-10-08 14:34:54 +00:00
2021-07-14 17:24:18 +00:00
void Platform_getBattery(double* percent, ACPresence* isOnAC);
static inline void Platform_getHostname(char* buffer, size_t size) {
Generic_hostname(buffer, size);
}
static inline void Platform_getRelease(char** string) {
*string = Generic_uname();
}
#define PLATFORM_LONG_OPTIONS
static inline void Platform_longOptionsUsage(ATTR_UNUSED const char* name) { }
static inline CommandLineStatus Platform_getLongOption(ATTR_UNUSED int opt, ATTR_UNUSED int argc, ATTR_UNUSED char** argv) {
return STATUS_ERROR_EXIT;
}
static inline void Platform_gettime_realtime(struct timeval* tv, uint64_t* msec) {
2021-07-14 17:15:09 +00:00
Generic_gettime_realtime(tv, msec);
}
void Platform_gettime_monotonic(uint64_t* msec);
static inline Hashtable* Platform_dynamicMeters(void) { return NULL; }
Add a new DynamicMeter class for runtime Meter extension This commit is based on exploratory work by Sohaib Mohamed. The end goal is two-fold - to support addition of Meters we build via configuration files for both the PCP platform and for scripts ( https://github.com/htop-dev/htop/issues/526 ) Here, we focus on generic code and the PCP support. A new class DynamicMeter is introduced - it uses the special case 'param' field handling that previously was used only by the CPUMeter, such that every runtime-configured Meter is given a unique identifier. Unlike with the CPUMeter this is used internally only. When reading/writing to htoprc instead of CPU(N) - where N is an integer param (CPU number) - we use the string name for each meter. For example, if we have a configuration for a DynamicMeter for some Redis metrics, we might read and write "Dynamic(redis)". This identifier is subsequently matched (back) up to the configuration file so we're able to re-create arbitrary user configurations. The PCP platform configuration file format is fairly simple. We expand configs from several directories, including the users homedir alongside htoprc (below htop/meters/) and also /etc/pcp/htop/meters. The format will be described via a new pcp-htop(5) man page, but its basically ini-style and each Meter has one or more metric expressions associated, as well as specifications for labels, color and so on via a dot separated notation for individual metrics within the Meter. A few initial sample configuration files are provided below ./pcp/meters that give the general idea. The PCP "derived" metric specification - see pmRegisterDerived(3) - is used as the syntax for specifying metrics in PCP DynamicMeters.
2021-06-23 07:44:56 +00:00
static inline void Platform_dynamicMetersDone(ATTR_UNUSED Hashtable* table) { }
Add a new DynamicMeter class for runtime Meter extension This commit is based on exploratory work by Sohaib Mohamed. The end goal is two-fold - to support addition of Meters we build via configuration files for both the PCP platform and for scripts ( https://github.com/htop-dev/htop/issues/526 ) Here, we focus on generic code and the PCP support. A new class DynamicMeter is introduced - it uses the special case 'param' field handling that previously was used only by the CPUMeter, such that every runtime-configured Meter is given a unique identifier. Unlike with the CPUMeter this is used internally only. When reading/writing to htoprc instead of CPU(N) - where N is an integer param (CPU number) - we use the string name for each meter. For example, if we have a configuration for a DynamicMeter for some Redis metrics, we might read and write "Dynamic(redis)". This identifier is subsequently matched (back) up to the configuration file so we're able to re-create arbitrary user configurations. The PCP platform configuration file format is fairly simple. We expand configs from several directories, including the users homedir alongside htoprc (below htop/meters/) and also /etc/pcp/htop/meters. The format will be described via a new pcp-htop(5) man page, but its basically ini-style and each Meter has one or more metric expressions associated, as well as specifications for labels, color and so on via a dot separated notation for individual metrics within the Meter. A few initial sample configuration files are provided below ./pcp/meters that give the general idea. The PCP "derived" metric specification - see pmRegisterDerived(3) - is used as the syntax for specifying metrics in PCP DynamicMeters.
2021-06-23 07:44:56 +00:00
static inline void Platform_dynamicMeterInit(ATTR_UNUSED Meter* meter) { }
static inline void Platform_dynamicMeterUpdateValues(ATTR_UNUSED Meter* meter) { }
static inline void Platform_dynamicMeterDisplay(ATTR_UNUSED const Meter* meter, ATTR_UNUSED RichString* out) { }
static inline Hashtable* Platform_dynamicColumns(void) { return NULL; }
static inline void Platform_dynamicColumnsDone(ATTR_UNUSED Hashtable* table) { }
static inline const char* Platform_dynamicColumnInit(ATTR_UNUSED unsigned int key) { return NULL; }
static inline bool Platform_dynamicColumnWriteField(ATTR_UNUSED const Process* proc, ATTR_UNUSED RichString* str, ATTR_UNUSED unsigned int key) { return false; }
#endif