This makes the behaviour consistent with other platforms where AC is
marked as present if at least one power source is marked as AC_PRESENT.
Fixes: #711
openbsd/OpenBSDProcessList.c:176:56: error: no member named 'ki_pid' in 'struct kinfo_proc'; did you mean 'p_pid'?
const int mib[] = { CTL_KERN, KERN_PROC_CWD, kproc->ki_pid };
^~~~~~
p_pid
/usr/include/sys/sysctl.h:375:10: note: 'p_pid' declared here
int32_t p_pid; /* PID_T: Process identifier. */
^
openbsd/OpenBSDProcessList.c:458:33: error: comparison of integers of different signs: 'int' and 'unsigned int' [-Werror,-Wsign-compare]
if (opl->cpus[i].cpuIndex == id)
~~~~~~~~~~~~~~~~~~~~~ ^ ~~
Currently htop does not support offline CPUs and hot-swapping, e.g. via
echo 0 > /sys/devices/system/cpu/cpu2/online
Split the current single cpuCount variable into activeCPUs and
existingCPUs.
Supersedes: #650
Related: #580
This adds a configure check for the ncurses getmouse() function
and disables mouse-related code paths when mouse support is
not present in the curses library.
This is necessary for stable versions of NetBSD's libcurses, the
development version has stub mouse functions for compatibility
with ncurses.
Signed-off-by: Nia Alarie <nia@NetBSD.org>
Before this change, the systemd meter was broken on distros like NixOS,
which have systemctl in PATH, but not at /bin/systemctl. After the
change, it works on all my NixOS machines.
It can happen that pcp-htop is presented multiple definitions
of the same dynamic meter, e.g. if /etc/pcp/htop/meters has a
definition matching one in ~/.config/htop/meters - instead of
exiting with a duplicate metric error provide more meaningful
diagnostics (on close) and also just skip over such entries.
System files override home directories which overrides those
found below the current working directory.
Also fix the derived metric error diagnostic; because this is
using CRT_fatalError, which is like perror(3), we must give a
meaningful prefix (like program name) at the string end.