Commit Graph

59 Commits

Author SHA1 Message Date
Volodymyr Vasiutyk
2ef70ad7f6 Early program termination only from main() 2021-10-31 15:07:00 +01:00
Silke Hofstra
696f79fe50 Dynamically scale the ST_UID size to support 32-bit UIDs
While most Unix-like systems use 16-bit user IDs,
Linux supports 32-bit UIDs since version 2.6.
UIDs above 65535 are used for UID namespacing of containers,
where a container has its own set of 16-bit user IDs.
Processes in such containers will have (much) larger UIDs than 65535.

Because the current format strings for `ST_UID` and `USER`
are `%5d` and `%9d` respectively, processes with such UIDs
lead to misaligned columns.

Dynamically scale the `ST_UID` column and increase the size of `USER`
to 10 characters (length of UINT32_MAX) to ensure that the user ID always fits.

Additionally: clean up how the titlebuffer size calculation and ensure
the PID column has a minimum size of 5.
2021-10-27 21:20:59 +02:00
Nathan Scott
8ac8542b6e Handle interrupted sampling from within libpcp PDU transfers
This situation can arise if pcp-htop screen is resized right
at the same time sampling from pmcd(1) is happening.  Have a
couple more goes at it before giving up entirely; once there
is no data available though we cannot proceed into accessing
the sample result data structure (segv will result) so a new
short-circuit guard is added there also.
2021-10-05 15:53:18 +11:00
Daniel Lange
94ad111391 Update license headers to explicitly say GPLv2+ 2021-09-22 14:28:19 +02:00
Nathan Scott
c0c2bb98a2 Add completion handling for dynamic meters and columns
Be sure to free dynamic memory allocated for meters and
columns strings, no-op on platforms other than pcp.

Closes #774
2021-09-03 09:47:01 +02:00
Christian Göttsche
25c945e2ef PCP: do not set exe to empty string
In case the executable is an empty string, e.g. if pcp is run by an
unprivileged user, do not set procExe to an empty value, which breaks
the formatting of the PROCEXE column and the merged-cmdline logic.
2021-09-02 23:37:53 +02:00
Christian Göttsche
b965417bf7 Add combined memory and swap meter
Closes: #699
2021-08-17 10:36:10 +02:00
Nathan Scott
d5ff5c48a8
Apply suggestions from code review
Co-authored-by: BenBE <BenBE@geshi.org>
2021-08-17 15:42:10 +10:00
Nathan Scott
c7f634ec21 PCP: ensure unsigned types used throughout CPU count detection
This cannot be negative in these code locations, but for the
purposes of static checking like Coverity scan make it clear
and used the same unsigned type as ProcessList.h for the CPU
count variable (matching PL activeCPUs and existingCPUs).
2021-08-17 14:41:55 +10:00
Nathan Scott
c401ac3a98 Ensure DynamicColumn hash lookups never see NULL pointers
This cannot happen in these code locations, but for the purposes
of static checkers like Coverity scan (and for future proofing),
add two more guards on NULL hash table entry pointers.
2021-08-17 14:41:40 +10:00
Sohaib
fefff80631 PCP: PCPMetric.[ch] Mdoule
Split the PCP Metric API (functions `Metric_*`) into their own module.
as @BenBE suggested.
2021-08-16 17:23:07 +02:00
Nathan Scott
f839095e3b Merge branch 'dynamic-columns' of https://github.com/smalinux/htop into smalinux-dynamic-columns 2021-08-13 15:56:01 +10:00
Sohaib Mohamed
6f2021f3d9 PCP: support for 'dynamic columns' added at runtime
Implements support for arbitrary Performance Co-Pilot
metrics with per-process instance domains to form new
htop columns.  The column-to-metric mappings are setup
using configuration files which will be documented via
man pages as part of a follow-up commit.

We provide an initial set of column configurations so
as to provide new capabilities to pcp-htop: including
configs for containers, open fd counts, scheduler run
queue time, tcp/udp bytes/calls sent/recv, delay acct,
virtual machine guests, detailed virtual memory, swap.

Note there is a change to the configuration file path
resolution algorithm introduced for 'dynamic meters'.
First, look in any custom PCP_HTOP_DIR location.  Then
iterate, in priority order, users home directory, then
local sysadmins files in /etc/pcp/htop, then readonly
configuration files below /usr/share/pcp/htop.  This
final location becomes the preferred place for our own
shipped meter and column files.

The Settings file (htoprc) writing code is updated to
not using the numeric identifier for dynamic columns.
The same strategy used for dynamic meters is used here
where we write Dynamic(name) so the name can be setup
once more at start.  Regular (static) columns writing
to htoprc - i.e. numerically indexed - is unchanged.
2021-08-13 07:32:57 +02:00
Nathan Scott
c31fd3c691 Merge branch 'pcp-dynamic-cpu' 2021-08-09 19:24:29 +10:00
Nathan Scott
1bd95983b2 Add columns for process autogroup identifier and nice value
Adds AGRP (autogroup) and ANI (autogroup nice) columns that
report the information from /proc/PID/autogroup, as well as
handlers for '{' and '}' to change the autogroup nice value.

This is guarded by /proc/sys/kernel/sched_autogroup_enabled
such that sampling and/or changing values wont be attempted
unless the kernel feature is enabled.

Fixes: #720
2021-08-09 07:56:13 +02:00
Nathan Scott
ee831263c3 PCP: implement a missing piece for offline and hotplug CPUs
Related: #656
2021-08-09 12:42:45 +10:00
Daniel Lange
ed82ce6456 Merge branch 'cpu_count' of cgzones/htop 2021-08-02 15:21:07 +02:00
Nathan Scott
19ad28a560 PCP: fix per-process user and system time conversions 2021-07-29 10:15:43 +02:00
Nathan Scott
97d9b320ad PCP: use the correct metric for shared memory calculations 2021-07-29 10:14:51 +02:00
Sohaib Mohamed
82aa956940 PCP: fixup: missing setter for isUserlandThread
fixes the color of PROC_COMM for PCP...
2021-07-18 10:28:52 +02:00
Christian Göttsche
11d2206f40 Add ProcessList_isCPUonline 2021-07-18 07:47:09 +02:00
Christian Göttsche
41af31be7f Rework CPU counting
Currently htop does not support offline CPUs and hot-swapping, e.g. via
    echo 0 > /sys/devices/system/cpu/cpu2/online

Split the current single cpuCount variable into activeCPUs and
existingCPUs.

Supersedes: #650
Related: #580
2021-07-18 07:44:02 +02:00
Benny Baumann
976c6123f4 Pointer indication aligned to typename 2021-07-15 06:57:24 +02:00
Benny Baumann
68edf92434 Indentation of string arguments 2021-07-15 06:57:24 +02:00
Benny Baumann
0d85af2872 Whitespace around operators 2021-07-15 06:57:24 +02:00
Benny Baumann
458749df45 Code indentation 2021-07-15 06:57:24 +02:00
Benny Baumann
e7f8d7bcc9 Split statements that should go onto multiple lines 2021-07-15 06:57:24 +02:00
Sohaib Mohamed
3853978538 PCP: cleanup: put ZFS in its rightful place
`PCPProcessList_updateHeader` for all meters...
2021-07-15 03:47:54 +02:00
Nathan Scott
2b69f44a9d Fix whitespace oddity in previous DynamicMeter updates
Thanks @BenBE for noticing.
2021-07-14 17:08:36 +10:00
Nathan Scott
0daefbe4b4 Improve the DynamicMeter_search API to make 'key' optional
Thanks to @BenBE for the suggestion.
2021-07-14 11:58:46 +10:00
Nathan Scott
9cbee01877 Additional pointer checks in dynamic meter code for Coverity 2021-07-14 11:58:46 +10:00
Nathan Scott
bf853addc3 Ensure PCP dynamic metric configuration definition uniqueness
It can happen that pcp-htop is presented multiple definitions
of the same dynamic meter, e.g. if /etc/pcp/htop/meters has a
definition matching one in ~/.config/htop/meters - instead of
exiting with a duplicate metric error provide more meaningful
diagnostics (on close) and also just skip over such entries.
System files override home directories which overrides those
found below the current working directory.

Also fix the derived metric error diagnostic; because this is
using CRT_fatalError, which is like perror(3), we must give a
meaningful prefix (like program name) at the string end.
2021-07-14 11:58:46 +10:00
Nathan Scott
e7aaf79166 Remove unnecessary include files from PCPDynamicMeter.c
Also resolve a few unintended style guide transgressions
in the PCP platform code.
2021-07-09 12:42:36 +10:00
Nathan Scott
01f5b89278 Pretty-print values in the PCP DynamicMeter code
Several improvements to the way values are displayed in the
PCP platform DynamicMeter implementation:
- handle the initial 'caption' setting as with regular meters,
  this required a new meter callback because we no longer have
  just a single meter caption for the DynamicMeter case
- if no label is provided for a metric in a configuration file
  use the short form metric name as a fallback
- honour the suffix setting in the configuration file
- convert metric values to the canonical units for htop (kbyte
  and seconds), and use Meter_humanUnit when it makes sense to
  do so.

Also improves the handling of fatal string error messages in a
couple of places, thanks to BenBE for the review feedback.
2021-07-08 10:56:05 +10:00
Nathan Scott
15a71f32fe Add more defensive checks to PCP paths if sampling fails 2021-07-07 14:00:36 +10:00
Sohaib Mohamed
93be3211ae PCP: use palette meter text colour for dynamic meter labels 2021-07-07 13:59:33 +10:00
Nathan Scott
f0ed0fdafb Add a new DynamicMeter class for runtime Meter extension
This commit is based on exploratory work by Sohaib Mohamed.
The end goal is two-fold - to support addition of Meters we
build via configuration files for both the PCP platform and
for scripts ( https://github.com/htop-dev/htop/issues/526 )

Here, we focus on generic code and the PCP support.  A new
class DynamicMeter is introduced - it uses the special case
'param' field handling that previously was used only by the
CPUMeter, such that every runtime-configured Meter is given
a unique identifier.  Unlike with the CPUMeter this is used
internally only.  When reading/writing to htoprc instead of
CPU(N) - where N is an integer param (CPU number) - we use
the string name for each meter.  For example, if we have a
configuration for a DynamicMeter for some Redis metrics, we
might read and write "Dynamic(redis)".  This identifier is
subsequently matched (back) up to the configuration file so
we're able to re-create arbitrary user configurations.

The PCP platform configuration file format is fairly simple.
We expand configs from several directories, including the
users homedir alongside htoprc (below htop/meters/) and also
/etc/pcp/htop/meters.  The format will be described via a
new pcp-htop(5) man page, but its basically ini-style and
each Meter has one or more metric expressions associated, as
well as specifications for labels, color and so on via a dot
separated notation for individual metrics within the Meter.

A few initial sample configuration files are provided below
./pcp/meters that give the general idea.  The PCP "derived"
metric specification - see pmRegisterDerived(3) - is used
as the syntax for specifying metrics in PCP DynamicMeters.
2021-07-07 10:59:36 +10:00
Nathan Scott
865b85eb2d Fix an assert on kernel process name length on the PCP platform 2021-07-07 10:59:36 +10:00
Sohaib Mohamed
ecb6a8da78 PCP: Fix minor cut+paste typo 2021-06-30 07:45:47 +02:00
Benny Baumann
1c0bd5155f PCP: Always update username 2021-06-22 09:32:11 +02:00
Nathan Scott
e3d0fc1a5a Fix a PCP diagnostics typo, add missing pmFreeResult null check. 2021-06-13 19:51:00 +02:00
Nathan Scott
0bd1025e94 Resolve a couple of recent memory leaks in pcp-htop
Makes the pcp-htop binary valgrind-clean once more.
2021-06-13 19:51:00 +02:00
Nathan Scott
94d37989b4 Use macros to PCPProcessList value extraction, tweak configure.ac
Resolves a couple of remaining review notes from @BenBE.
2021-06-09 17:09:29 +10:00
Nathan Scott
144fd0a8d7 Update platform-specific header includes to use pcp paths.
Resolves a couple of remaining review notes from @BenBE.
2021-06-09 17:09:29 +10:00
Nathan Scott
4bcb5d116b Update the PCP platform to use common Process fields and code
Remove code now that we have common platform-independent command
line wrangling (thanks BenBE!).  Add PCP platform support for a
handful of other recently arriving odds and ends - ELAPSED time,
CWD, and so on.
2021-06-09 17:09:29 +10:00
Nathan Scott
4d7cee56f0 Rework TTY column for the PCP platform 2021-06-09 17:09:29 +10:00
Nathan Scott
9ce9557e69 Various code tidyups based on review commentary from BenBE 2021-06-09 17:09:29 +10:00
Nathan Scott
b232119e4b Resolve some Coverity scan misfires in PCP platform code 2021-06-09 17:09:29 +10:00
Nathan Scott
da454997bf Remove dynamic allocation of PCP metric atomvalues expansion
This is no longer used and confuses Coverity scans, drop it.
2021-06-09 17:09:29 +10:00
Nathan Scott
d4a2587568 Add time handling interfaces for the pcp platform
Related to https://github.com/htop-dev/htop/pull/574
2021-06-09 17:09:29 +10:00